Research and Production Enterprise

+7 (34767) 5-09-77

Order call

Regenerative heat exchanger

 

The regenerative heat exchanger blowdown of the primary circuit ТК80W01 (hereinafter "exchanger") is part of the system makeup and blowdown of the primary circuit. Heat exchanger designed for cooling of purge water from the primary circuit, while heating make-up water.

 

Characteristics

Cooling side - tube side

Cooling side - shell side

Environment

Energized water

Purge water

Heat exchange surface, m2

107

107

Design pressure, МPа (kgs/sm2)

19,5(198,9)

19,5(198,9)

Design temperature, °С

350

350

Water temperature end, °С

to 309,4

до 134

Water temperature initial, °С

tо 68,8

до 350

Pressure hydraulic test, МPа (kgs/sm2)

30,5 (311,1)

30,5 (311,1)

Consumption (nominal), t/h

30

30

Расход (максимальный), t/h

80

80

Pressure loss, МPа

0,21

0,13