STEAM-WATER HEATERS

Intended use:

Steam-water heaters are designated for chemically purified water heating by heating steam heat utilization at heat power plants and boiler houses.

Steam-water heaters may also be applied for water heating at heat distribution points (room heating, swimming pool water heating, showers, etc.).

Steam-water heaters are manufactured in compliance with reservoir regulations of Federal Mining and Industrial Supervision Committee of Russia, but are not subject to registration therein.

Technical specifications:

Parameter

Heat exchanger type

Q=50 т/ч

Q=100 т/ч

Q=200 т/ч

Q=400 т/ч

Heating surface, m²

8,4

15,6

31,2

68

Maximum pressure, MPa

steam

   0,7

water

   0,7

Max. steam temperature, ˚С

 180

Heat exchange pipes diameter, mm

                                                    16x1

Number of heat exchange pipes

86

330

322

584

 Number of ways

steam

2

water 

                           

2

4

2

2

Heater shell diameter, mm

273

478

478

630

Heater length, mm 

2403

1665

2705

3180

Dry weight, kg

330

560

794

1400