STEAM-WATER HEATERS
Intended use:
Steam-water heaters are designated for chemically purified water heating by heating steam heat utilization at heat power plants and boiler houses.
Steam-water heaters may also be applied for water heating at heat distribution points (room heating, swimming pool water heating, showers, etc.).
Steam-water heaters are manufactured in compliance with reservoir regulations of Federal Mining and Industrial Supervision Committee of Russia, but are not subject to registration therein.
Technical specifications: | ||||||
---|---|---|---|---|---|---|
Parameter | Heat exchanger type | |||||
Q=50 т/ч | Q=100 т/ч | Q=200 т/ч | Q=400 т/ч | |||
Heating surface, m² | 8,4 | 15,6 | 31,2 | 68 | ||
Maximum pressure, MPa | steam | 0,7 | ||||
water | 0,7 | |||||
Max. steam temperature, ˚С | 180 | |||||
Heat exchange pipes diameter, mm | 16x1 | |||||
Number of heat exchange pipes | 86 | 330 | 322 | 584 | ||
Number of ways | steam | 2 | ||||
water |
2 | 4 | 2 | 2 | ||
Heater shell diameter, mm | 273 | 478 | 478 | 630 | ||
Heater length, mm | 2403 | 1665 | 2705 | 3180 | ||
Dry weight, kg | 330 | 560 | 794 | 1400 |